Condition Monitoring with COIN Cell and COIN Pro with Probe used for cold storage to check low temperature and check higher temperatures by using the probe submerged in Water and Oil respectively (both, at room temperature and boiling temperature).
Comments are closed.
Shopping Basket
Test Items
Test Results
Test Conditions
Moisture resistance test
After test, no obvious change in appearance, and function was normal.
Temperature varied from 25°C±2K to 65°C±2 K
Relative humidity at (93±3)%
High temperature test
After test, no obvious change in appearance, and function was normal
High temperature: 60°C
Test duration: 96H
Low temperature Test
After test, no obvious change in appearance, and function was normal.
Low temperature:-10°C
Test time: 96H
Heat cycle test
After test, no obvious change in appearance, and function was normal
Temperature rise 60°C 1H
Operating 60°C 6H
Temperature
processing -10°C 2H
Operation -10°C 6H
Repeated 60H
Continuous vibration
After test, no obvious mechanical damage, and function was normal.
Condition A:
Amplitude:0.25 mm or less
Frequency: 5±1Hz~50±1Hz
Test direction: X, Y, Z axis
Test time: 10min/cycle, 5 cycles/direction
Condition B:
Acceleration:2.0 m/s2 or less
Frequency: 5±1Hz~50±1Hz
Test direction: X, Y, Z axis
Test duration: 10min/cycle, 5 cycles/direction
Impact test
After test, no obvious mechanical damage, and function was normal.