In Mining Industries, maintaining the record of trip count manually was difficult. There was no proper transparency & also data loss was occurring, while adding manually. Also after completion of a trip, identifying wait time of the trucks was not possible. The time taken by the excavators to load the truck was unknown. Identifying loading of truck by the excavators particularly was not possible and also trip counts per day could not be tracked. With SenseGiz’s Asset Tracking solution, we could help the mining industry by solving all these problems along with benefits like, Reduced manual entry of the trip counts & data fetching at any point of time. Loading & unloading time of the trucks could be easily identified. Also increase in efficiency by reducing the wait time could be seen. Keeping track of the unloading data at each hopper location, as well as truck loading for each day could be monitored.
Coin attached to vehicles for trip count
Mining Vehicles
Coin attached to vehicles for trip count
sensegiz mining solution
Comments are closed.
Shopping Basket
Test Items
Test Results
Test Conditions
Moisture resistance test
After test, no obvious change in appearance, and function was normal.
Temperature varied from 25°C±2K to 65°C±2 K
Relative humidity at (93±3)%
High temperature test
After test, no obvious change in appearance, and function was normal
High temperature: 60°C
Test duration: 96H
Low temperature Test
After test, no obvious change in appearance, and function was normal.
Low temperature:-10°C
Test time: 96H
Heat cycle test
After test, no obvious change in appearance, and function was normal
Temperature rise 60°C 1H
Operating 60°C 6H
Temperature
processing -10°C 2H
Operation -10°C 6H
Repeated 60H
Continuous vibration
After test, no obvious mechanical damage, and function was normal.
Condition A:
Amplitude:0.25 mm or less
Frequency: 5±1Hz~50±1Hz
Test direction: X, Y, Z axis
Test time: 10min/cycle, 5 cycles/direction
Condition B:
Acceleration:2.0 m/s2 or less
Frequency: 5±1Hz~50±1Hz
Test direction: X, Y, Z axis
Test duration: 10min/cycle, 5 cycles/direction
Impact test
After test, no obvious mechanical damage, and function was normal.